Go to homepage

Electrotherapy device PHYSIODYN-Expert (3rd edition)

Electrotherapy device PHYSIODYN-Expert (3rd edition)

CHF 4,300.—

For instalment payments up to 36 months, please contact us by e-mail.

excl. VAT, plus. Shipping costs

Product number: PH-Elphe3
Manufaturer: PHYSIOMED
Product information "Electrotherapy device PHYSIODYN-Expert (3rd edition)"

Stimulation current therapy with 21 current forms

Professional electrotherapy and diagnostics for clinics, rehabilitation centres and physiotherapy practices.
Highlights:
  • New user interface - for super-fast and clear operation
  • Indication list with filter function - Intelligent filter functions of the indication list by body region, desired therapy effect or alphabet for a quick search for the desired treatment suggestion
  • User guidance and overview - Perfected user guidance through a combination of 7" touchscreen and PHYSIOMED single-button operation for a comprehensive overview of all therapy parameters and therapy timer; multifunctional intensity control with intensity comfort threshold and for quick channel change.
  • Favourites menu - makes it impressively easy to save and call up the most popular applications - just two clicks to therapy!
  • Memory menu - Easy-to-use and comprehensive memory menu with treatment sequences and history function
  • I/T curve - with graphic visualisation of the curve progression
  • Warnings - Warnings when intensity is exceeded.
  • Colour coding - Logical colour coding of the stimulation current and vacuum application accessories for quick and reliable assignment of the channels and the respective polarity.
Clean currents
Quite a few electrotherapy devices today no longer emit stimulation currents in the form found in textbooks and proven to be the basis of efficient electrotherapy. Instead - mainly for reasons of cost savings - similar but not identical waveforms are used, of which nobody knows exactly whether they produce the desired effects in the tissue in the same way as the original currents. For example, low-frequency currents are generated from medium-frequency currents and vice versa. The difference between "real" and "similar" currents can often be felt in direct comparison, but it only becomes visible when looking at the current curves on the oscilloscope. There you will find galvanic currents with spikes, angular instead of harmonic sine curves or equally unclean envelope curves of diadynamic currents.
PHYSIOMED The company distances itself resolutely from the trend of risking therapeutic success simply to maximise profits and only uses "clean" currents in its therapy devices. This also explains why we often hear competent electrotherapy users say that they have better therapeutic success with PHYSIOMED devices than with other stimulation current devices, despite the same parameters.
Stimulation current therapy
  • Dual-channel electrotherapy with 21 current forms
  • Alternating and simultaneous stimulation
  • Spasticity treatment
  • Hand button as emergency stop switch or for intention exercises (optional)
  • Warnings when intensity is exceeded
  • Vacuum application with PHYSIOVAC-Expert (optional)
Medium-frequency current forms:
  • IF (classic interference current)
  • AMF (amplitude-modulated medium-frequency current)
  • MT (medium-frequency muscle stimulation)
  • KOTS (Russian stimulation)
  • Low-frequency forms of current:
G (galvanisation)
GMC (galvanisation with microcurrent)
DF (diadynamic current diphasé fixe)
MF (diadynamic current monophasé fixe)
CP (diadynamic current modulé en courtes périodes)
LP (diadynamic current modulé en longues périodes)
UR (Ultra stimulation current according to Träbert)
HV (high voltage current)
TENS (Transcutaneous Electrical Nerve Stimulation)
MENS (electrical nerve stimulation with microcurrent)
IG 30 (impulse galvanisation 30)
IG 50 (pulse galvanisation 50)
FM (frequency modulated current)
STOCH (stochastic current)
FaS (Faradic threshold current)
HVS (high voltage stimulation)
T/R (exponential current)
Diagnostics:
  • Faradic excitability test
  • Medium frequency test according to Lange
  • Accommodation quotient
  • Rheobase/chronaxy
  • I/T curve (with graphical representation of the curve progression)
  • I/T curve - rapid test
General features:
  • Perfected user guidance through a combination of 7" touchscreen and PHYSIOMED single-button operation
  • Comprehensive overview of the therapy parameters currently in use at all times, including all therapy timers
  • Comprehensive indication list with notes on therapy, dosage suggestions, treatment images and intelligent filter functions by body region, desired therapy effect or alphabet for a quick search for the desired treatment suggestion
  • Easy-to-use and comprehensive memory menu with treatment sequences and history function
  • Multifunctional intensity control with intensity/comfort threshold
  • Logical colour coding of the stimulation current and vacuum application accessories for quick and reliable assignment of the channels and the respective polarity
  • SD card slot for product updates
Therapy information:
Stimulation current therapy is an important component of electrotherapy. Stimulation currents are transmitted to the tissue to be treated via electrodes (plate electrodes, vacuum electrodes, adhesive electrodes). Depending on the form of current and the choice of parameters (i.e. pulse form, pulse duration, pause time, frequency, intensity), stimulation currents can have the following main effects in the treatment area:
Pain reduction:
  • stimulation of blood circulation and trophic improvement
  • Nerve stimulation, especially for innervation training and paralysis treatment
  • Muscle stimulation for muscle development and maintenance
  • Muscular detonation
  • Iontophoresis
The following classification of the various stimulation currents can be made according to their origin and specific mode of action in the tissue:
Medium-frequency currents: these are alternating currents that are generated by superimposing a base frequency (2-9.5 KHz) with a modulation frequency (0-250 Hz). In the case of AMF current (amplitude-modulated medium-frequency current) and medium-frequency currents for muscle stimulation (MT and KOTS), this superimposition already takes place in the device. The pre-modulated current can therefore be delivered to the patient via only two electrodes. In contrast, with the classic IF interference current, the two frequencies are only superimposed in the patient's tissue, which is why four electrodes are always required for treatment. The high therapeutic effectiveness of medium-frequency currents is due to their minimal skin irritation with a pronounced depth effect and therefore good acceptance by the patient.
Pulse currents with frequencies below 1000 Hz are considered to be low frequency. The various low-frequency currents DF, MF, CP, LP (diadynamic currents), UR (ultra stimulation current), HV (high-voltage current), FaS (faradic threshold current), TENS (mono- or bidirectional rectangular pulses) and T/R (exponential current) can be used to cover the entire range of applications mentioned above. In contrast to medium-frequency currents, certain low-frequency currents can also be used to treat peripheral paralyses.
Galvanic current (G) is a direct current that flows through the tissue with constant energy. Galvanic current is mainly used to stimulate blood circulation and reduce pain as well as for iontophoresis (application of a preparation with the help of the current).
Therapeutic and diagnostic possibilities
  • Electrotherapy has an enormously wide range of applications. Among other things, it is ideal for the treatment of
  • Osteoarthritis (knee joint)
  • Acceleration trauma CRPS stage I and II
  • Chondropathia patellae
  • Epicondylitis
  • joint effusion
  • Radicular syndrome
  • Pain syndrome, postoperative
  • Spasticity treatment according to Hufschmidt/Jantsch
  • Ankylosing spondylitis

Technical data (Fig. 16)

Standard accessories:
  • Elasticated fabric tape (10 x 125 cm)
  • Elastic fabric tape (6 x 80 cm)
  • Instructions for use
  • Brief introduction to stimulation current therapy
  • Mains cable
  • Patient cable
  • EF 50 plate electrodes
  • Viscose bags EF 50

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Loading...
Files are being uploaded, please wait...